<< Click to Display Table of Contents >> Navigation: ANSDIMAT+ > Aquifer tests analysis > Graphical analysis > Straight-line method > ANSDIMAT+ > Aquifer tests analysis > Graphical analysis > straight-line method >Slug test |
The "Solution for slug test" dialog prompts to choose a solution for slug test analysis by the straight-line method on a time-distance plot. The solution is selected considering conceptual model and test conditions.
"Solution for slug test" dialog.
Explanatory table
"Bouwer-Rice: unconfined aquifer" option |
Bouwer-Rice’s solution for a partially penetrating well in unconfined aquifer |
"Hvorslev: confined aquifer" option |
Hvorslev’s solution for a partially penetrating well in the top of confined aquifer |
"Hvorslev: confined aquifer, piezometer" option |
Hvorslev’s solution for a penetrating well located in the aquitard and penetrating the confined aquifer by its bottom |
"Hvorslev: unconfined aquifer" option |
Hvorslev’s solution for a partially penetrating well in unconfined aquifer |
"Hvorslev: unconfined aquifer, piezometer" option |
Hvorslev’s solution for a partially penetrating well in unconfined aquifer when only the lower part of the screen is open |
"Anisotropy factor" text box |
Specifies the profile anisotropy coefficient used in Hvorslev’s solutions |
"Casing radius" text box |
Specifies the casing radius of the pumping well |