<< Click to Display Table of Contents >> Navigation: Hydrogeologist workbench (ANSQUICK) > Drawdown during aquifer tests > Leaky aquifer > ANSQUICK > Drawdown during aquifer tests > Leaky aquifer >Variable level in adjacent aquifer |
See section: Alternating water level in the adjacent aquifer.
"Leaky aquifer: variable level in adjacent aquifer" dialog box.
Explanatory table
"Q, m^3/day" text box |
Constant pumping rate of a well |
"t, day" text box |
Time for which drawdown is calculated |
"s, m" text box |
This field shows calculated drawdown. Entering a value in this field re-calculates the pumping rate |
"T2, m^2/day" text box |
Transmissivity of the adjacent aquifer |
"a2, m^2/day" text box |
Hydraulic diffusivity of the adjacent aquifer |
"s2, m" text box |
This field shows calculated drawdown in the adjacent aquifer |
"B2, m" text box |
Leaky factor for the adjacent aquifer |
"k, m/day" text box |
Hydraulic conductivity of the main aquifer |
"a, m^2/day" text box |
Hydraulic diffusivity of the the main aquifer |
"B, m" text box |
Leaky factor of the main aquifer |
"m, m" text box |
Main aquifer thickness |
"r, m" text box |
Distance from the pumping well to an observation well |
"T, m^2/day" text box |
Transmissivity of the main aquifer |
"S, --" text box |
Storage coefficient of the main aquifer |
"Ss, 1/m" text box |
Specific storage of the main aquifer |