ANSQUICK > Drawdown during aquifer tests >

Confined infinite aquifer

<< Click to Display Table of Contents >>

Navigation:  Hydrogeologist workbench (ANSQUICK) > Drawdown during aquifer tests >

ANSQUICK > Drawdown during aquifer tests >

Confined infinite aquifer

See section: confined infinite aquifer.

 

"Confined aquifer" dialog box.

 

Explanatory table

"Q, m^3/day" text box

Constant pumping rate of a well

"ε, m/day"  text box

Recharge rate

"t, day" text box

Time for which drawdown is calculated

"s, m" text box

This field shows calculated drawdown. When value is entered in this field, pumping rate is calculated

"k, m/day" text box

Hydraulic conductivity of aquifer

"a, m^2/day" text box

Hydraulic diffusivity of aquifer

"m, m" text box

Aquifer thickness

"r, m" text box

Distance from the pumping well to an observation well

"T, m^2/day" text box

Transmissivity of aquifer

"S, --" text box

Storage coefficient of aquifer

"Ss, 1/m" text box

Specific storage of aquifer

 

Equiation: