<< Click to Display Table of Contents >> Navigation: Hydrogeologist workbench (ANSQUICK) > Drawdown during aquifer tests > ANSQUICK > Drawdown during aquifer tests >Semi-infinite aquifer |
See section: I kind, II kind and III kind (river), and leaky.
"Semi-infinite aquifer" dialog box.
Explanatory table
"Q, m^3/day" text box |
Constant pumping rate of a well |
"t, day" text box |
Time for which drawdown is calculated |
"s, m" text box |
This field shows calculated drawdown. Entering a value in this field re-calculates the pumping rate |
"I" option |
Boundary condition of I kind (recharge boundary) |
"II" option |
Boundary condition of II kind (no-flow boundary) |
"III" option |
Boundary condition of III kind (river) |
"k, m/day" text box |
Hydraulic conductivity of aquifer |
"a, m^2/day" text box |
Hydraulic diffusivity of aquifer |
"dL, m" text box (for III kind) "B, m" text box (for leaky aquifer) |
Retardation coefficient of stream bed Leaky factor |
"m, m" text box |
Aquifer thickness |
"Steady-state" option |
Steady-state drawdown |
"Leaky" option |
Leaky aquifer |
"Calculate parameter" option |
Calculate hydraulic conductivity by pumping rate and drawdown |
"r, m" text box |
Distance from the pumping well to an observation well |
"Lw, m" text box |
Distance from pumping well to boundary |
"Lp, m" text box |
Distance from observation well to boundary |
"T, m^2/day" text box |
Transmissivity of aquifer |
"S, --" text box |
Storage coefficient of aquifer |
"Ss, 1/m" text box |
Specific storage of aquifer |